1Phase / 1Phase UPS

img

1Phase / 1Phase UPS (5kVA to 10kVA)

Single-Phase Configuration: Both the input and output power are single-phase, meaning they consist of a single AC waveform. This configuration is typically used in applications where the power load is relatively smaller and can be handled effectively by single-phase equipment.

Capacity (3 to 10 kVA): This specifies the capacity range of the UPS system, which is between 3 kilovolt-amperes (kVA) and 10 kVA.

Suitability: Single-phase UPS systems in this capacity range are often used in small to medium-sized businesses, individual workstations, small server rooms, medical equipment, and other applications where a moderate level of power protection and backup is required.


  • Small to medium-sized offices
  • Retail stores
  • Critical equipment in industrial settings
  • Medical and healthcare facilities
  • Any environment where uninterrupted power supply is critical for operations

Compact Design: Designed to be compact and space-efficient, suitable for installations where space is limited.

Easy Installation: Typically designed for easy installation and setup, often including features like plug-and-play connectivity.

Basic Monitoring and Management: May include basic monitoring and management features to ensure the UPS operates effectively and can be monitored remotely if needed.

Backup Power: Provides backup power in case of mains power failure, ensuring continuity of operations for connected equipment.

MODEL AGU 1Ø Input - 1Ø Output
Technology DSP with IGBT
CAPACITY 5 KVA 6 KVA 7.5 KVA 10 KVA
DC BUS 120V / 192V 120V / 192V 192V / 240VDC 192V / 240V
INPUT
Input Voltage 230V AC Single Ø
Input power factor @ 100% Load 0.99
Input current harmonic distortion (THDi) <10%
Input Voltage Window 170-270V
Input Frequency 50Hz ± 10%
Rectifier IGBT based full bridge
Voltage Regulation ( ± ) 1%
Charger Type CVCC
OUTPUT
Inverter Type IGBT based MPWM with instantaneous Sinewave Control
Power Factor 0.8 lag
Nominal Voltage 230V Single Ø
Regulation ( ± ) 1%
Frequency 50Hz ± 1 Hz
Total Harmonic Distortion < 2% for linear load, < 6% for non linear load
Over Load Capacity 125% - 1 Minute : 150% 5 Seconds
Transient Response Remains within +/- 5% & recover to normal within 20 msec
Nominal output current 17.3 A 20.8 A 26.0 A 34.7 A
Crest Factor 3:1
Mode of Operation Designed for Continuous operation
EFFICIENCY
Efficiency- 100 % load 87%
Converter Protection Advanced Electronic Protection for device safety backed up with MCB's & fast acting fuses
ISOLATION
Inverter Protection True Online with complete galvanic isolation for comprehensive power protection.
• Advanced Electronic Protection for device safety
• Backed up with MCB's & fast acting fuses
• High speed pulse by pulse electronic device protection
• Over voltage / under voltage protection
• Electronic over current trip with reset
ENVIRONMENTAL
Acoustic Noise level <60db @ 1.5 meter
Ambient Temperature 0 to 40 Deg C
Humidity Up to 95% RH Non condensing
Altitude < 3000 Feet above sea level (without derating)
PHYSICAL
Enclosure Protection IP-20
Cooling Forced Air
Cable Entry Back side bottom
Dimensions in mm- D x H x W & Weight (Approximate) 530 x 550 x 210 / 45Kg 530 x 550 x 210 / 50Kg 530 x 550 x 210 / 55Kg 640 x 660 x 240 / 75Kg
LED Indications • Mains on • Charger on • Inverter on • Battery Low • Overload • Inverter Trip
Protections • Input Fuse • Input Under Voltage / Over Voltage • Rectifier Over Voltage • Over Temperature Protection • Battery Low protection • Over Load protection • Short circuit protection • High voltage transient protection & Electrostatic discharge protection
Compatibility Remote power monitoring using SNMP Software & Solar Power
Testing Standard As per IEC 62040-3